Date: 11/19/2010 | Time: 12:21 PM | Report ID: 1119104478 |
Property: |
Customer: |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Age Of Home: Over 10 Years | Home Faces: South | Client Is Present: Yes |
Radon Test: No | Water Test: No | Weather: Cloudy |
Temperature: Below 40 | Percipitation in last 3 days: No |
FOUNDATION: POURED CONCRETE | METHOD USED TO OBSERVE CRAWLSPACE: FROM ENTRY | FLOOR STRUCTURE: 2 X 10 WOOD JOISTS |
WALL STRUCTURE: 2 X 4 WOOD | COLUMNS OR PIERS: STEEL LALLY COLUMNS | CEILING STRUCTURE: 4" OR BETTER |
ROOF STRUCTURE: ENGINERED WOOD TRUSS OSB | ROOF-TYPE: GABLE | METHOD USED TO OBSERVE ATTIC: FROM ENTRY |
ATTIC INFO: SCUTTLE HOLE |
Inspection Items
|
1.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) Comments: Inspected, In good condition |
1.1 | WALLS (Structural) Comments: Inspected, In good condition |
1.2 | COLUMNS OR PIERS Comments: Inspected, In good condition |
1.3 | FLOORS (Structural) Comments: Inspected, Repair or Replace | |
The wood shims at the bottom of the I beam should be replace with steel shims.(Picture 1)
|
1.4 | CEILINGS (structural) Comments: Inspected, In good condition |
1.5 | ROOF STRUCTURE AND ATTIC Comments: Inspected, In good condition |
SIDING MATERIAL: MASONRY VINYL | SIDING STYLE: BEVEL | EXTERIOR ENTRY DOORS: STEEL |
APPURTENANCE: COVERED PORCH | AUTO OPENER MANUFACTURER: DELTA DOOR | GARAGE DOOR MATERIAL: INSULATED METAL |
GARAGE DOOR TYPE: THREE AUTOMATIC | DRIVEWAY: CONCRETE |
Inspection Items
|
2.0 | WALL CLADDING FLASHING AND TRIM Comments: Inspected, Repair or Replace | ||||||
The wood trim at the overhead door is rotted on the bottom.
The wood trim at the fireplace chimney has been damaged from a woodpecker.(Picture 2) The front brick is cracked and is allowing water to leak into the office ceiling,(Picture 3)(Picture 4)(Picture 5) The fascia at the northwest corner is not sealed tight.(Picture 6)
|
2.1 | DOORS (Exterior) Comments: Inspected, Repair or Replace | |
The front door lock latch dose not retract completely(Picture 1). The strike plate needs to be adjusted so the
door seals tight.
|
2.2 | WINDOWS Comments: Inspected, In good condition |
2.3 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) Comments: Inspected, Repair or Replace | |
The north overhead door has face damage.(Picture 1)
Garage overhead door operator will not reverse when met with resistance.
|
2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS Comments: Inspected, In good condition |
2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) Comments: Inspected, Repair or Replace | ||
(1) Negative grade found at north side and west side of house. Areas with negative grade should be raised at
structure to help push water away from foundation and prevent water intrusion and deterioration.(Picture 1)
| |||
(2) A half-round window well should be installed around vent openings to allow for grade to be raised. The dirt inside
well should be replaced with approximately four or more inches of gravel to let water drain from well. A couple of
inches clearance between gravel and window or vent openings recommended.(Picture 3)
|
2.6 | EAVES, SOFFITS AND FASCIAS Comments: Inspected, In good condition |
ROOF COVERING: ARCHITECTURAL | VIEWED ROOF COVERING FROM: LADDER WALKED ROOF | CHIMNEY (exterior): METAL FLUE PIPE |
Inspection Items
|
3.0 | ROOF COVERINGS Comments: Inspected, In good condition |
3.1 | FLASHINGS Comments: Inspected, In good condition |
3.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Comments: Inspected, In good condition |
3.3 | ROOFING DRAINAGE SYSTEMS Comments: Inspected, Repair or Replace | |
The gutter at the garage roof at the front of the house is not fastened to the wall.(Picture 1)
|
WATER SOURCE: PUBLIC | PLUMBING SUPPLY: COPPER | PLUMBING DISTRIBUTION: COPPER |
PLUMBING WASTE: PVC | WATER HEATER POWER SOURCE: GAS (QUICK RECOVERY) | CAPACITY: 40 GAL (1-2 PEOPLE) |
MANUFACTURER: GE | WASHER DRAIN SIZE: 2" DIAMETER |
Inspection Items
|
4.0 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS Comments: Inspected, In good condition |
4.1 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments: Inspected, In good condition, Repair or Replace | |
The boiler drain on the waterheater is leaking.(Picture 1)
|
4.2 | MAIN WATER SHUT-OFF DEVICE (Describe location) Comments: Inspected |
4.3 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments: Inspected, Repair or Replace | ||
The water valve that supplies the lawn irrigation is leaking.(Picture 1)(Picture 2)
|
4.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Comments: Inspected, In good condition |
4.5 | SUMP PUMP Comments: Inspected, In good condition |
Recommend installing a siphon back up sump pump that runs off city water pressure to prevent basement from flooding incase of a loss of power. |
ELECTRICAL SERVICE CONDUCTORS: BELOW GROUND ALUMINUM 220 VOLTS | PANEL CAPACITY: 200 AMP | PANEL TYPE: CIRCUIT BREAKERS |
ELEC. PANEL MANUFACTURER: SQUARE D | BRANCH WIRE 15 and 20 AMP: COPPER | WIRING METHODS: ROMEX |
Inspection Items
|
5.0 | SERVICE ENTRANCE CONDUCTORS Comments: Inspected, In good condition |
5.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS Comments: Inspected, In good condition |
5.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE Comments: Inspected, In good condition |
5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Comments: Inspected, Repair or Replace | |
The microwave plug is loose in the wall.(Picture 1)
|
5.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Comments: Inspected, In good condition |
5.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Comments: Inspected, In good condition |
5.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS Comments: Inspected, In good condition |
Main panel box is located at basement. |
5.7 | SMOKE DETECTORS Comments: Inspected, In good condition |
The smoke detectors were tested and did alarming when a smoke test is performed. |
HEAT TYPE: FORCED AIR | ENERGY SOURCE: NATURAL GAS | NUMBER OF HEAT SYSTEMS (excluding wood): ONE |
HEAT SYSTEM BRAND: LENNOX | DUCTWORK: NON-INSULATED | FILTER TYPE: DISPOSABLE CARTRIDGE |
TYPES OF FIREPLACES: VENTED GAS LOGS | OPERABLE FIREPLACES: NONE |
Inspection Items
|
6.0 | HEATING EQUIPMENT Comments: Inspected, In good condition |
No carbon monoxide was detected at the time of this inspection. |
6.1 | NORMAL OPERATING CONTROLS Comments: Inspected, In good condition |
6.2 | AUTOMATIC SAFETY CONTROLS Comments: Inspected, In good condition |
6.3 | CHIMNEYS, FLUES AND VENTS Comments: Inspected, In good condition |
6.4 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments: Inspected, In good condition |
6.5 | GAS/LP FIRELOGS AND FIREPLACES Comments: Inspected | |
The gas valve is off.(Picture 1)
|
6.6 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Comments: Inspected, In good condition |
COOLING EQUIPMENT TYPE: AIR CONDITIONER UNIT | COOLING EQUIPMENT ENERGY SOURCE: ELECTRICITY | NUMBER OF A/C UNITS: ONE |
Inspection Items
|
7.0 | COOLING AND AIR HANDLER EQUIPMENT Comments: Not Inspected |
A/C was not tested for proper operation due to the outside air temperature is 65 degrees or less. We did not inspect this unit (S). |
7.1 | NORMAL OPERATING CONTROLS Comments: Inspected, In good condition |
7.2 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments: Inspected, In good condition |
7.3 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM Comments: Inspected, In good condition |
CEILING MATERIALS: SHEETROCK | WALL MATERIAL: SHEETROCK | FLOOR COVERING(S): CARPET TILE VINYL |
INTERIOR DOORS: HOLLOW CORE MASONITE RAISED PANEL | WINDOW TYPES: THERMAL/INSULATED DOUBLE-HUNG | WINDOW MANUFACTURER: ANDERSEN |
CABINETRY: WOOD | COUNTERTOP: TILE |
Inspection Items
|
8.0 | CEILINGS Comments: Inspected, Repair or Replace | |||
The office ceiling is water damaged.(Picture 1)
The dry wall inside corners are loose at the the family room ceilings.(Picture 2) The dry wall ceilings in the master bedroom is poorly installed. The drywall is loose at the east wall.(Picture 3)
|
8.1 | WALLS Comments: Inspected, In good condition |
8.2 | FLOORS Comments: Inspected, Repair or Replace | |
All of the carpets are stained.(Picture 1)
|
8.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments: Inspected, In good condition |
8.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments: Inspected, In good condition |
8.5 | DOORS (REPRESENTATIVE NUMBER) Comments: Inspected, Repair or Replace | |
The upstairs hall bathroom door door dose not latch.(Picture 1)
|
8.6 | WINDOWS (REPRESENTATIVE NUMBER) Comments: Inspected, In good condition |
ATTIC INSULATION: CELLULOSE | R- VALUE: R-19 OR BETTER | VENTILATION: GABLE VENTS SOFFIT VENTS |
EXHAUST FAN TYPES: FAN WITH LIGHT | DRYER POWER SOURCE: 22O ELECTRIC | DRYER VENT: FLEXIBLE METAL |
Inspection Items
|
9.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) Comments: Inspected, Repair or Replace |
Recommend adding insulation in attic space so there is 14 or more inches to obtain a R-value of R-42 or greater. |
9.1 | VENTILATION OF ATTIC AND FOUNDATION AREAS Comments: Inspected | |
I recommend installing 6 mil visqueen on the dirt floor in the crawl space.(Picture 1)
|
9.2 | VENTING SYSTEMS (Kitchens, baths and laundry) Comments: Inspected, Repair or Replace | |
The west side vent dose not close and the vent needs to be replaced.(Picture 1)
|
Inspection Items
|
10.0 | DISHWASHER Comments: Inspected, In good condition |
10.1 | RANGES/OVENS/COOKTOPS Comments: Inspected, In good condition |
10.2 | RANGE HOOD Comments: Inspected, In good condition |
10.3 | FOOD WASTE DISPOSER Comments: Inspected |
10.4 | MICROWAVE COOKING EQUIPMENT Comments: Inspected, In good condition |
4418 South Nine Mile Road
Auburn Mi 48611
989-662-9378
Customer
Sample
Address
Michigan
1. STRUCTURAL COMPONENTS | |||||||||
|
2. EXTERIOR | ||||||||||||||||||||||||||||||||||||
|
3. ROOFING | |||||||||
|
4. PLUMBING SYSTEM | ||||||||||||||||||
|
5. ELECTRICAL SYSTEMS | |||||||||
|
8. INTERIORS | |||||||||||||||||||||||||||
|
9. INSULATION AND VENTILATION | ||||||||||||||||||
|
(PLEASE READ CAREFULLY)
Van Wert Inspections agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property, subject to the UNCONDITIONAL RELEASE AND LIMITATION OF LIABILITY below. The inspection and report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT. The report will only include the following:
It is understood and agreed that this inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing only at the time of the inspection. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items, and systems will not be dismantled.
Maintenance and other items may be discussed, but they are not a part of our inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind.
The inspection and report do not address and are not intended to address the possible presence of or danger from any potentially harmful substances and environmental hazards, including but not limited to radon gas, lead paint, asbestos, mold, mildew, urea formaldehyde, toxic or flammable chemicals, and water and airborne hazards. Also excluded are inspections of and reports on swimming pools, wells, septic systems, security systems, central vacuum systems, water softeners, sprinkler systems, fire and safety equipment, and the presence or absence of rodents, termites and other insects.
UNCONDITIONAL RELEASE AND LIMITATION OF LIABILITY
It is understood and agreed that Van Wert Inspections is not an insurer and that the inspection and reports are not to be intended or construed as a guarantee or warranty of the adequacy, performance, or condition of any structure, item, or system at the property address. The CLIENT hereby releases and exempts Van Wert Inspections and its employees of and from all liability and responsibility for the cost of repairing or replacing any unreported defect or deficiency and for any consequential damage, property damage, or personal injury of any nature.
In the event that Van Wert Inspections and/or its employees are found liable due to breach of contract, negligence, negligent misrepresentation, negligent hiring or any other theory of liability, then the liability of Van Wert Inspections and employees shall be limited to a sum equal to the amount of the fee paid by the CLIENT to Van Wert Inspections for the inspection and report.
CLIENT and Van Wert Inspections agree that should a court of competent jurisdiction determine and declare that any portion of this Agreements is void, voidable or unenforceable, the remaining provision and portion shall remain in full force and effect.
Acceptance and understanding of this agreement are hereby acknowledged:
________________________________
_________________________________
Company Representative Date Client Date